Acer

ECM Fan Motor Won’t Turn On or Won’t Shut Off on HVAC

ECM Fan Motor Won’t Turn On or Won’t Shut Off on HVAC Unit! Testing the Board and Fan Motor!

#ECM #Fan #Motor #Wont #Turn #Wont #Shut #HVAC

“AC Service Tech LLC”

In this HVAC Training Video, I Show how to Troubleshoot Whether the ECM Fan Motor or the Main Circuit Board in the Furnace or Air Handler is Bad. I Show the Measurement Points to be Able to Diagnose This Effectively When the Fan Either Won’t Turn On or Won’t Shut Off. ECM Constant Torque and ECM…

source

 

To see the full content, share this page by clicking one of the buttons below

Related Articles

28 Comments

  1. Like craig Said. Fails at the Module. not the motor I know This for sure. Because I've Fixed.six ECM motor instead of replacing the module or the motor itself. On the high voltage side of the module There is a component on the board that is called a rush current limiter. This component, after a period of a few years blows a leg off the board. Due to heating of the component. $3 part from Melzer electronics out a Texas and you're up and running again. The latest one that I Fixed. Was Six years old and The rush current limiter blow a leg off the one side of the Component.. replaced with new one And still going 4 years now.

  2. Excellent video, I recommend your videos to any of my friends who are interested in learning controls. It amazes me how how thorough your training is. I have gone to training that cost money that were not as good as your videos.

  3. If itโ€™s an air handler here in the Pacific Northwest then you might see 256 volts at the blower in one neighborhood and 207 volts at a residential home a couple of blocks awayโ€ฆ Ya our power grid is screwed up here

  4. I was struggling to understand how te controls work. Then I did a plc training (aka siemens logo programming ๐Ÿ˜…) and now I understand all electronic boards are basically logos without the coverage, with the difference that they are already programmed

  5. I know you have the heart of a teacher, but you should CHARGE for all this knowledge. Case in point… you saved my son at least $300 plus in labor. He calls me up… 8 year old Bryant heat pump. Blower with an X13 would run all the time. Using one of your videos… I pulled the thermostat and it still ran. Checked G to C no voltage. Pulled the fan speed wires on the X13… still ran. Bad module. Replaced it with the Rescue Ez13 because it had both pigtails. All is well. i charged him a 12 pack of beer. ๐Ÿ˜

  6. Six years ago my Rheem air handler ecm fan motor stopped working. I determined the ecm fan module went bad – I assume it was from a voltage surge from a storm around that time. I was able to locate and purchase a new GE gentec module on eBay for $250 (the dealer flashed/programmed the replacement module for my specific system application). I did not purchase a new complete GE gentec ecm motor assy as at that time it was $700. The air handler fan motor w/the replacement fan control module is still working fine to this day. Properly diagnosing the module as the issue for fan not working was very difficult as all I had to go on was the wiring diagrams located on the air handler. At that time I didn't even know that an ecm fan assy that uses DC power to operate the fan motor was a thing. Had I had this video back then as an explanation of system operation it'd of saved me several hours of troubleshooting. Back then I couldn't find any info online on how the ecm fan motors worked or their elec/system diagnosis procedures.

  7. As always I like your videos every day I work as residential PM technician and these videos are great resource to refresh my knowledge. Again as always your one the top technician and teacherโ€ฆ

  8. I've literally diagnosed three bad ecm motors this past week! All three of the customers said they were running their furnaces on a generator (generac).

    Another great video, Craig! I appreciate what you do for this community!

Leave a Reply