We turn on and we see fault code 03 (bus soft start fail)
Disassembly & general check
Check The INV Full Bridge IGBT: Shorted
Check Buck IGBT: Shorted
(60G65WE)
Check Output capacitors 20uF/350VAC: Normal
Replacing The INV Full Bridge and Buck IGBT
there is a damaged PCB PAD & Broken PCB Trace…